Locked out? Call 604-227-908324/7 emergency · Vancouver · Kitsilano · West End · East VanNo hidden feesLicensed & insuredShop safes, smart locks & key blanks Locked out? Call 604-227-908324/7 emergency · Vancouver · Kitsilano · West End · East VanNo hidden feesLicensed & insuredShop safes, smart locks & key blanks

Hager – 4701 FIRE RATED RIM 36” / 4700 Series / ALM / Push Bar Exit Device – Grade 1 / EO / REV 2

Inquire

Priced on request. Tell us the quantity you need and whether it needs cutting or programming, and we'll quote you.

Request a quote · +16042279083 → Inquire online →
Questions before you buy? Call us — we'll confirm fit, stock and install options before anything is cut or programmed.

Details

- Hager 4700 Series exit device meets Life Safety codes and Fire Safety requirements providing a perfect fit for use in light commercial and standard duty applications

- The 4700 Series is UL305 Panic Listed and UL and cUL listed for up to 3 hour rated fire doors for the Rim device and 1-1/2 hours for the Surface Vertical Rod device

- The 4700 Series Rim device also meets the requirements of ANSI A250.13 to be listed as a Severe Windstorm Resistant Component

- It is constructed with die cast head covers and is packaged for convenience and versatility with thru-bolts included

- The 4700 Series has a five-year warranty for devices and trims

- Product Group
4700 Series Standard Duty Exit Devices
- Product Type
Rim Device (RIM)
- Size
36″ (914 mm) Length
- Finish
Aluminum (ALM)
- Door Thickness
1-3/4″ (44 mm)
- Certifications
ANSI A250.13 Severe Windstorm Resistant Component (Rim device only UL/cUL Listed for up to 3 hours for “A” labeled doors UL10C/UBC 7-2 (1997) Positive Pressure Rated UL10B Neutral Pressure Rated Hex dogging feature standard on non-fire labeled doors UL305 Listed for panic hardware Complies with ANSI 117.1 for accessible buildings and facilities
- Applications
Light commercial and Standard duty commercial
- Finishes
US3, US32D, ALM, DBZ
- Covers
Casted brass, bronze, stainless steel, zinc
- Cover Tube
Painted steel, plated steel, stainless steel
- End Caps
Painted steel, plated steel, stainless steel
- Door Width
36” (914 mm) field sizeable to 30” (762 mm) door 48” (1219 mm) field sizeable to 36” (914 mm) door
- Door Thickness
1-3/4″ (44 mm) – Standard
- Stile Width
4-1/2” (114 mm) – Minimum stile width required for single door and 5/8″ (16 mm) stop) 4-1/2” (114 mm) – Minimum stile width required for double door x surface vertical rod device with double door strike 3-3/4″ (95 mm) – minimum stile width required for double door x mullion x 4920 strike 5″ (127 mm) – Minimum stile width required for double doors with 2″ (51 mm) mullion All stile widths are measured from door edge
- Trim
Archer, August, William or Withnell lever with escutcheon Archer, August, Withnell lever with key-in-lever trim Raised lip pull Pull plate trim Rim cylinder x optional pull
- Fasteners
Wood and machine screws Thru-bolts
- Latchbolt
5/8″ (16 mm) throw, pullman type with automatic dead-latching, stainless steel
- Strikes
Stainless steel with roller – Included standard with panic and fire rated devices Surface applied to frame with slotted holes for easy adjustment Optional double door strike for use with surface vertical rod and rim devices
- Projection
2-7/16″ (62 mm) in undogged position 1-3/16″ (30 mm) in dogged position
- Case Quantity
3
- Sold
Per Piece
- Notes
Cylinders sold separately Recommended to be used on appropriately reinforced doors